Shenzhen Kinda Technology Co., Ltd

Shenzhen Kinda Technology Co., Ltd

Manufacturer from China
Active Member
7 Years
Home / Products / Water Pump Controller /

Single Phase Automatic Motor Pump Controller , Auto Water Tank Controller 220V~240V

Contact Now
Shenzhen Kinda Technology Co., Ltd
City:shenzhen
Province/State:guangdong
Country/Region:china
Contact Person:MrTim
Contact Now

Single Phase Automatic Motor Pump Controller , Auto Water Tank Controller 220V~240V

Ask Latest Price
Video Channel
Brand Name :Kinda
Model Number :PC
Place of Origin :China
MOQ :10PCS
Price :10USD~50USD
Payment Terms :T/T
Supply Ability :10~100000
Delivery Time :3~7Day
Pump Protection :Protection Functions Such As Overload, No Load, And Ultra Low Voltage
Memory :Fault Memory Function, 5 Reasons For Failure Can Be Found
Power :0.4KW~15KW
PCB Protection :Spray Three Anti-paint To Protect The Circuit Board Intelligently And Efficiently
Control :Main/slave Control Energy Saving
Control Distance :The Longest Control Distance Is 500 Meters
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Single-phase automatic water pump controller 220V~240V

The automatic pump controller is simple and efficient. When the pump is started to pump water, it is often forgotten to shut it down, resulting in waste of electricity and water. The installation of the fully automatic pump is simple and efficient to solve the start and stop of the pump. When the pool is filled with high water level, the pump water supply is stopped by the sensor signal. When the pool is at low water level, the sensor signal starts the pump to pump water.

The automatic water pump controller adopts digital core with overload, no load and ultra low voltage protection. The upper and lower levels and pressure are automatically controlled in one.

Can be connected to float control, pressure gauge control and probe sensor control

Technical Specifications

Item Technical Index Specification
Input Input voltage 1AC 220V±15%,
3AC 220V±15%
3AC 380V±15%
Input frequency 50/60Hz±5%
Self-consumed power Standby state <3.5W
Running state <4.5W
Default setting No-load current 0.0A
No-load restart time 30 minutes
Control distance Maximum control distances 500m
Overload protection time Inverse time limit
(±15% time error
120% / 50s
150% / 30s
200% / 15s
300% / 6s
500% / 1s

Selection Guide

Inverter Model Suitable motor Pump quantity Breaker
Single phase 220V
PC1-S2-1500 0.37~1.5kW 1 No
PC1-S2-2200 0.37~2.2kW 1 No
PC2-S2-2200B 0.37~2.2kW 2 Build-in
Three phase 220V
PC1-T2-2200 0.37~2.2kW 1 No
PC1-T2-2200B 0.37~2.2kW 1 Build-in
PC2-T2-2200B 0.37~2.2kW 2 Build-in
PC1-T2-4000 1.0~4.0kW 1 No
PC1-T2-4000B 1.0~4.0kW 1 Build-in
PC2-T2-4000B 1.0~4.0kW 2 Build-in
PC1-T2-7500B 1.0~7.5kW 1 Build-in
PC2-T2-7500B 1.0~7.5kW 2 Build-in
Three phase 380V
PC1-T4-2200 0.37~2.2kW 1 No
PC1-T4-2200B 0.37~2.2kW 1 Build-in
PC2-T4-2200B 0.37~2.2kW 2 Build-in
PC1-T4-4000 1.0~4.0kW 1 No
PC1-T4-4000B 1.0~4.0kW 1 Build-in
PC2-T4-4000B 1.0~4.0kW 2 Build-in
PC1-T4-7500 1.0~7.5kW 1 No
PC1-T4-7500B 1.0~7.5kW 1 Build-in
PC2-T4-7500B 1.0~7.5kW 2 Build-in
PC1-T4-11000B 2.2~11kW 1 Build-in
PC2-T4-11000B 2.2~11kW 2 Build-in
PC1-T4-15000B 2.2~15kW 1 Build-in
PC2-T4-15000B 2.2~15kW 2 Build-in

Wiring connection of float switch for upper pool water level control

Single Phase Automatic Motor Pump Controller , Auto Water Tank Controller 220V~240V

The common terminal of float switch connect to the low level terminal of controller, short connect high
& middle level terminals of controller and connect to the normal open terminal of float switch.

Wiring connection of float switch for lower pool water level control

Single Phase Automatic Motor Pump Controller , Auto Water Tank Controller 220V~240V

The common terminal of float switch connect to the low level terminal of controller, short connect high
& middle level terminals of controller and connect to the normal close terminal of float switch.

Inquiry Cart 0